Victron MPPT Charge Controller Open-loop Configuration Procedure
During normal operation, the MPPT charge characteristics are governed by the Victron GX device in a closed-loop configuration based on data and charge requests provided by the connected Discover Lithium battery.
When closed-loop communication has failed, the MPPT needs to be reset and reconfigured to use open-loop communication. Simply cycling the power does not reset the charger.
To remove the charger from a closed-loop system and use it in a system without a BMS:
The Victron Connect Bluetooth App is used to configure, monitor, and diagnose Victron MPPT Charge Controller products equipped with Bluetooth. | ![]() Victron Connect Bluetooth App |
Victron Connect Bluetooth App > Device List > Victron MPPT > Settings > Battery
MPPT Battery Settings Menu | AES RACKMOUNT | HELIOS ESS |
---|---|---|
Battery voltage | 48 V | 48 V |
Max charge current (1) | Number of batteries x 95 A | Number of batteries x 200 A |
Charger enabled | Enabled | Enabled |
Battery preset | User Defined | User Defined |
Expert mode | Disabled | Disabled |
Absorption voltage | 55.2 V | 55.2 V |
Float voltage | 53.6 V | 53.6 V |
Equalization voltage | 55.2 V | 55.2 V |
Automatic equalization | Disabled | Disabled |
Temperature compensation | Disabled | Disabled |
Low temperature cut-off | < 4°C (39.2°F) | < 4°C (39.2°F) |
Maximum absorption time (2) | 1.0 < 3.0 Hr | 1.0 < 3.0 Hr |
(1) May be set to a lower value if necessitated by charger controller size.
(2) When editing battery presets, set the duration of the absorption period, which occurs after the bulk charge interval. The recommended minimum is 1.0 hour. Multiple batteries may require a longer time to achieve a smooth completion of charge.