ENABLING LYNK II TO COMMUNICATE WITH SOLIS DEVICES

When properly connected to a closed-loop network and set to use the Solis protocol, LYNK II will transmit real-time parameters from the Discover Lithium battery, including voltage, current, temperature, state of charge, and fault conditions to a Solis inverter-charger. LYNK II will also transmit charge voltage and current requests from the Discover Lithium battery to a Solis inverter-charger.

LYNK ACCESS software for 64-bit Windows 10 / 11 is required to configure LYNK II settings for closed-loop CAN communication with Solis inverter-chargers.

If there is a break in communication between the LYNK II and the inverter-charger for a few seconds, the inverter-charger will safely stop operation. The Solis inverter-charger will check every few minutes and resume closed-loop operation if communication is re-established. However, if communication cannot be re-established and you need to resume operation, you will have to manually convert the Solis inverter to an open-loop configuration. Refer to A.1 Solis Open-Loop Configuration.

NOTE

Neither Discover Lithium batteries nor LYNK II directly control Solis relay functions, generator starting or other grid-interactive features. These functions are controlled through the programming of the Solis inverter-charger.