Skip to main content
Skip table of contents

Victron Inverter-Charger Open-loop Configuration Procedure

Refer to the latest Discover Energy Systems documentation for battery values and the latest Victron documentation for details on menu navigation and the setup procedure.

  1. Set the Discover Lithium batteries to ON and set the inverter to ON.

  2. Connect your computer to the Victron GX device or inverter.

  3. On the computer, start the VE Configure 3 software configuration tool.

  4. Enable and disable parameter values according to the tables below.

  5. Send the parameters to the Victron inverter-charger and GX device.

  6. Toggle the On/Off/Charger Only switch to turn the inverter OFF and ON.

VE Configure 3 > General Tab

General Tab

AES RACKMOUNT
48-48-5120 / 48-48-5120-H

HELIOS ESS
52-48-16000

[AC1] Overruled by remote (1)

Enable

Enable

[AC2] Overruled by remote (1)

Enable

Enable

Dynamic current limiter

Enable

Enable

External current sensor connected

Disable

Disable

Enable battery monitor

Enable

Enable

State of charge when Bulk finished (2)

95%

95%

Battery capacity

Number of batteries x 100 Ah

Number of batteries x 314 Ah

Charge efficiency (2)

1.00

1.00

(1) Enable is recommended.
(2) Precautionary settings ignored during normal operation and communication with Discover lithium batteries.

VE Configure 3 > Inverter Tab

Inverter Tab

AES RACKMOUNT
48-48-5120 / 48-48-5120-H

HELIOS ESS
52-48-16000

DC input low shutdown (1)

48.0 V

DC input low restart (2)

52.0 V

DC input low pre-alarm (3)

49.5 V

Enable AES (4)

Disable

(1) The lowest operating voltage allowed. Increase voltage as required.

(2) Restart voltage after DC input low shutdown. Recommend setting to the minimum value (minimum varies according to the DC Input low shutdown value).

(3) 49.5 V / 24.75 V value (approximately 10% SOC) will trigger a low battery warning. Increase or decrease as preferred.

(4) ‘Enable AES’ has no relation to either the AES RACKMOUNT or HELIOS ESS battery. Refer to Victron manuals for information on the AES setting and function.

VE Configure 3 > Charger Tab

Charger Tab

AES RACKMOUNT
48-48-5120 / 48-48-5120-H

HELIOS ESS
52-48-16000

Enable charger

Enable

Enable

Battery Type (1)

Blank

Blank

Lithium Batteries (1)

Enable

Enable

Charge Curve (1)

Select: Fixed

Select: Fixed

Absorption Voltage (1)

55.2 V

55.2 V

Float Voltage (1)

53.6 V

53.6 V

Charge Current

Number of batteries x 95 A

Number of batteries x 200 A

Repeated absorption time (1)(2)

1.0 < 3.0 Hr

1.0 < 3.0 Hr

Repeated absorption interval(1)

7.0 Days

7.0 Days

Absorption time (1)(2)

1.00 < 3.0 Hr

1.00 < 3.0 Hr

(1) Precautionary settings ignored during normal operation and communication with Discover lithium batteries.

(2) The recommended minimum is 1.0 hour. Multiple batteries may require a longer time to achieve a smooth completion of charge.

NOTE

Confirm the Float Voltage after installation of any Victron ’Assistants’, and if necessary, set the Float Voltage back to 53.6 V.