Schneider Electric
NOTICE |
|---|
EQUIPMENT DAMAGE When operating in a closed loop, the BMS communicates the internal battery temperature with Schneider Electric devices. Remove any temperature sensors from inverters or charge controllers so they do not override or conflict with the BMS. Failure to follow these instructions may result in equipment damage. |
This section provides information about integrating LYNK and AEbus network-enabled Discover Lithium Batteries using the LYNK II Communication Gateway with Schneider Electric power conversion devices in a closed-loop configuration.
Before installation and configuration, consult the relevant product documentation, including Manuals, Application Notes, and Installation and Configuration Guides.
Schneider Electric Documentation
Visit solar.se.com for the most recent version of published documents.
Discover Energy Systems Documentation
Visit https://www.discoverenergysys.com for the most recent version of published documents.
AES RACKMOUNT Installation and Operation Manual (805-0043)
AES RACKMOUNT datasheet (808-0039)
HELIOS ESS Installation and Operation Manual (805-0090)
HELIOS ESS datasheet (808-0046)
Discover Lithium Batteries
A Discover battery must have a compatible network port, such as a LYNK Port or AEbus Port, for communicating with a LYNK II device.
AES RACKMOUNT: 48-48-5120
HELIOS ESS: 52-48-16000
Schneider Electric Inverters
The LYNK II Communication Gateway is compatible with the following Schneider Electric devices.
Schneider Electric Equipment | |
|---|---|
XW PRO | XW+ |
Compatible SE Products | |
MPPT 60-150 | Conext XW+ 5.5/6.8 |
There are three different ways to connect to Schneider Electric devices.
Xanbus Protocol (over the Xanbus Network)
Schneider BMS (through the LYNK II phoenix connector and InsightHome/InsightFacility)
LV BMS Protocol (through InsightHome/InsightFacility)