Leaving the battery connected to a trickle load or power electronics will cause the battery to discharge during storage. Without any load, the battery will self-discharge by approximately 3.5% per month while in storage. After storage, charge the battery to 100% SOC and perform at least one full discharge and charge cycle before returning the battery to service.
-
Store at 95% SOC or more. To store the battery for up to 6 months, store the battery at 95% SOC or more. It must remain disconnected from all loads and power electronics during storage.
-
Switch OFF the battery. Set the battery to OFF.
-
Check SOC every six months. Recharge the battery to above 95% SOC every six months.
-
Proper storage temperature. Ensure storage is within the temperatures specified below.
-
1 Month storage temperature -20°C to 55°C (-4°F to 131°F)
-
6 Month storage temperature -10°C to 30°C (14°F to 86°F)
-
|
NOTICE |
|---|
|
VOID WARRANTY
Failure to follow these instructions may result in equipment damage. |
|
NOTICE |
|---|
|
BATTERY DAMAGE
Failure to follow these instructions may result in equipment damage. |