805-0092 AES 210HV Installation Manual

Battery Pack

74dadf9b-d089-4366-9fb2-b68599079bd4.png

Battery Pack

No.

Name

Description

1

Battery Pack Coolant Inlet/Outlet

Connects the battery pack to the Thermal Management System, facilitating the flow of coolant for temperature regulation.

2

Battery Pack Pressure Relief Valve

If a thermal event occurs inside the battery pack, the valve indicator will pop forward and release the internal aerogel to suppress a thermal runaway event.

3

Battery Pack Communication Harness

This connects the battery pack to the High Voltage Control Box for communication and monitoring.

4

Manual Service Disconnect (MSD)

The MSD includes a 500 A fuse. Use the MSD to manually disconnect high-voltage circuits in the battery pack during transportation, installation, maintenance, or emergencies.

5

B-

Battery Pack Negative (-) Terminal, used for the negative connection of the battery pack.

6

B+

Battery Pack Positive (+) Terminal, used for the positive connection of the battery pack.

Not Shown

Internal Fire Suppression

The integrated pack-level fire suppression system is located behind the right access panel.