Enabling LYNK II to Communicate with Luxpower Devices
When properly connected to a closed-loop network and set to use the Luxpower protocol, LYNK II will transmit real-time parameters from the Discover Lithium battery, including voltage, current, temperature, state of charge, and fault conditions, to a Luxpower inverter-charger. LYNK II will also transmit charge voltage and current requests from the Discover Lithium battery to a Luxpower inverter-charger.
LYNK ACCESS software for 64-bit Windows 10 / 11 is required to configure LYNK II settings for closed-loop CAN communication with Luxpower inverter-chargers.
When the Luxpower inverter is configured in a closed loop with Discover Lithium batteries and the communication breaks between the LYNK II and inverter, after about a minute, the inverter safely stops operation and displays an alarm. If communication is re-established, the Luxpower inverter resumes closed-loop operation within seconds. However, if communication cannot be reestablished and you need to resume operation, you may have to manually convert the Luxpower inverter-charger to an open-loop configuration. Refer to Luxpower Open-loop Configuration.