Minimum Battery System Capacity

The LYNK II Communication Gateway unlocks the full potential of a Discover Lithium battery by enabling the internal Battery Management System (BMS) to provide real-time data in a closed-loop configuration to other devices. This configuration allows hybrid inverter-chargers and solar charge controller systems to optimize control over the charging process in solar applications. LYNK II also enables the remote monitoring of Discover Lithium battery SOC and data logging of multiple sites using the data monitoring services offered by off-grid inverter systems.

Discover Lithium batteries must be set up to work with power conversion and monitoring devices in either an open-loop or closed-loop configuration.

In an open-loop configuration, charge and discharge settings are set up manually through the controller for the power conversion device at the time of installation.

In a closed-loop configuration, the BMS of the Discover Lithium battery sends the battery status over a network data connection with the power conversion device. Power conversion devices use the Discover Lithium battery BMS data to fine-tune the output of their charger as well as deliver other functional controls based on battery voltage, temperature, and percent State-of-Charge.

If communication between the BMS and Morningstar power conversion device is interrupted, the power conversion device faults after a few seconds and stops the charging process. If communication between the BMS and the Morningstar power conversion device is restored, the fault is cleared and charging continues.

Morningstar 48V Systems

Continuous Max Amps DC (1)

AES RACKMOUNT 48-48-5120/ 48-48-5120-H

Recommended per inverter (2)

HELIOS ESS 52-48-16000

Recommended per inverter (3)

GS-MPPT-60M-200V

60 A

1

1

GS-MPPT-80M-200V

80 A

1

1

GS-MPPT-100M-200V

100 A

2

1

(1) Data based on max amps in GenStar MPPT datasheet, Control #MS-003676 01/30/2022.

(2) Discover AES RACKMOUNT 48-48-5120/48-48-5120-H Battery, Peak Power (3 seconds): 218 A RMS, 95 A DC Continuous Charge/Discharge (1 hour), as published in Discover AES RACKMOUNT Installation and Operation Manual (805-0043 Rev F).

(3) Discover HELIOS ESS 52-48-16000 Battery, Peak Discharge Current (15 seconds): 300 A RMS, 200 A DC Max Continuous Charge/Discharge, as published in Discover HELIOS ESS Installation and Operation Manual (805-0090 Rev E).

 