Enabling LYNK II to Communicate with Morningstar Devices

When properly connected to a closed-loop network and set to use the Morningstar protocol, LYNK II will transmit real-time parameters from the Discover Lithium battery, including voltage, current, temperature, state of charge, and fault conditions to the Morningstar power conversion device. LYNK II will also transmit charge voltage and current requests from the Discover Lithium battery to Morningstar devices.

LYNK ACCESS software for 64-bit Windows 10 is required to configure LYNK II settings for closed-loop communication with devices on a Morningstar network.

Use Morningstar Live View 2.0 to configure the Morningstar power conversion devices.

If communication between LYNK II and the Morningstar power conversion device is lost for a few seconds, the Morningstar device shows the fault status on its LED, displays a fault number, and stops. The Morningstar power conversion device automatically continues its operation once communication with the LYNK II is re-established.