Internal Heating

The HELIOS ESS battery is equipped with internal heating. When the battery’s internal temperature is below 5°C (41°F) and the battery is either connected to a charging source or SOC is 50% or more, energy is diverted to the internal heater to avoid the under-temperature fault.

The heating stops when:

  1. The battery’s internal temperature reaches 8°C (46.4°F).

  • Once the cell temperature reaches this threshold, all the energy is directed to charging the cells.

  1. No charge current is detected and SOC is less than 50%.

  • After the heating stops, if the battery’s internal temperature drops below 5°C (41°F) and the battery is connected to a charging source, the heater turns ON again.

For information about internal heating, refer to Protection Specifications and Internal Heating Specifications.

NOTE

Charging and heating can occur simultaneously. However, the BMS will not allow charging to continue when cell temperature drops below 4°C (39.2°F) for 5 seconds.