Charger Settings
InsightLocal > Devices > MPPT Charge Controller > Configuration (Advanced) > Charger Settings
|
InsightLocal > Charger Settings |
Description |
|---|---|
|
Equalization Voltage Set Point (V) |
In a closed-loop system, the BMS disables this property. A Lithium battery should never be equalized. |
|
Equalize Support (Yes/No) |
|
|
Bulk/Boost Voltage Set Point (V) |
In a closed-loop system, the BMS disables this property. |
|
Float Voltage Set Point (V) |
|
|
Recharge Voltage (V) |
When the Charge Cycle is set to 3-Stage, ReCharge Voltage will be Disabled (Ignore any value displayed). |
|
Absorption Voltage Set Point (V) |
In a closed-loop system, the BMS programs this property. |
|
Absorption Time (Minutes) |
|
|
Charge Cycle (3 Stage, 2 Stage) |
Set to 3-stage to provide current for base loads. |
|
Maximum Charge Rate (%) |
Default: 100% If required, use this setting to de-rate the charger output of each device in the system. This is not a system-wide setting. The maximum charging current delivered by the entire system should not exceed the maximum charge current rating of the entire battery system. |
|
Equalize Now (Enabled/Disabled) |
In a closed-loop system, the BMS disables this property. |
|
Default Battery Temperature (Hot, Warm, Cold) |
Default: Warm. When operating in a closed loop, the BMS communicates the internal battery temperature. |
Battery Settings
InsightLocal > Devices > MPPT Charge Controller > Configuration (Advanced) > Battery Settings
|
NOTE |
|---|
|
If closed-loop communication fails, the MPPT Solar Charge Controllers continue to operate in the state they were in before communication was lost. |
|
InsightLocal > Battery |
Description |
|---|---|
|
Battery Type (Flooded, GEL, AGM, Custom) |
Set to Custom. |
|
Nominal Battery Voltage (24 V / 48 V) |
Set to 48 V.
|
|
Battery Bank Capacity (Ah) |
Set to the number of batteries in the system multiplied by the Discover Lithium battery's rated capacity.
|
|
Battery Temperature Coefficient (mV/°C) |
Recommended: 0 mV/°C. In a closed-loop system, the BMS communicates the battery voltage based on the internal battery temperature. |